Certification Manual
- 87 -
Chapter 9 – Troubleshooting Nurse Call
Problems
Wireless Nurse Call Problems
Supervisories
Control Panel Automation Supervisory
Control Panel Connection Problem
Control Panel Com Port Problem
1. Clear the error (right click, acknowledge) and see if it goes away
2. Check Hardware Components Power
3. Check serial cable connections
4. Check com port settings on the AllCall software and Device Manager
5. Check lights on Automation Module.
WaveWare Connection Problem
WaveWare Com Port Problem
1. Clear the error (right click, acknowledge) and see if it goes away.
2. Check the Paging Encoder power
3. Check the serial cable connections
4. Check the com port settings on the AllCall software and Device
Manager
Point xyz Low Battery
1. Replace battery in call station transmitter.
Point xyz RF Supervisory Failure
1. Replace battery in call station transmitter.
2. Check wireless coverage. (Zone test on touchpad and alarm zone,
refer to touchpad commands section)
3. If the zone is a wireless pendant, ensure that it has not left the
campus.
Point xyz Tamper Problem
1. Replace cover back on call station transmitter and clear error.
2. Inside transmitter, stretch out the spring so that it is compressed
properly with transmitter lid in place.